SIEMENS | Fire & Smoke Electronic Damper Actuators


Solution_Partner_standard_dark_background.png
 

Please contact our Sales Team for a price quote for products or installation.

Need Help Logo (grey-round).JPG

The right fire and smoke device matters when lives matter. Reduce risk with OpenAir™

A comprehensive fire and life safety plan requires a strategic combination of fire and smoke detection, suppression and containment for both active and passive fire protection. Fire and smoke dampers help contain smoke, toxic gases and fire from spreading throughout the building to aid protection of people, property and assets. The right device matters to operate a fire and smoke damper system…not only is it important to meet UL555 and UL555S standards, it’s imperative the devices used mitigate any risk to life safety, are long-lasting and reliable when needed. OpenAir™ actuators uniquely integrate with our patented electronic fusible link for reduced risk and improved protection.

 
Siemens Fire & Smoke Actuators.jpg

Fire & Smoke Electronic Damper Actuators

OVERVIEW

OpenAir fire and smoke damper actuators meet the UL555S standard and the damper manufacturers carry the UL555S listing with their assemblies (damper + actuator). The actuators uniquely integrate with our patented electronic fusible link using a low-voltage electrical connection. With other brands, damper assemblies and installations can vary drastically. OpenAir's unique integrated design changes the game. No extra hardware is required (junction box, conduit, etc.) and everything easily goes together improving assembly consistency and eliminating risk of faulty installation.

FEATURES

Actuators:

  • Maximum drive torque: 35 lb-in

  • Spring return torque: 35 lb-in

  • Temperature rating: 250º F / 30 minutes

  • 30-second drive open and 15-second spring return

  • Anti-rotation bracket mounted

  • Optional auxiliary switch versions available

  • Built-in electronic fusible link capability

  • Plenum-rated, pre-cabled

  • Made in the USA

Electronic Fusible Link:

  • Three temperature ratings 165° F, 212° F, and 250° F

  • Does not require conduit since wired to low-voltage side of actuator

  • Plenum-rated

  • Only manufacturer who provides electronic fusible link compatible with fire/smoke damper actuator

  • Manual override reset button – simplifies testing and inspection process

APPLICATIONS

  • Fume hoods

  • Exhaust and supply dampers

  • Combination fire and smoke dampers

 

Fire & Smoke Damper graphic.png

Product Downloads

sie-logo-layer-claim-petrol-rgb.png

Fire + Smoke Damper Actuators | Data sheets, manuals, brochures, and more

Fire + Smoke Damper OpenAir Actuators | Brochure

Fire + Smoke OpenAir Damper Actuators | Overview Brochure

Fire + Smoke Damper Actuators | Behind the Innovation Video

Fire + Smoke OpenAir Damper Actuators | Installation Video

Fire + Smoke Damper Actuators | Cross Reference quide