The right device for managing energy consumption while optimizing comfort.
Easy-to-use and highly reliable BT300 variable frequency drives reduce the cost of installation and maintenance while maximizing energy savings. The drive keypad features built-in wizards that get HVAC equipment up and running quickly and accurately. Anyone can safely and quickly commission the BT300 using default parameters that are optimized for typical HVAC applications.
BT300 Series
OVERVIEW
Siemens BT300 is designed specifically for the demands of today’s HVAC systems. Increased focus on energy efficiency of variable flow systems has increased the need for easy-to-use and highly reliable variable frequency drives to reduce the cost of installation and maintenance while maximizing energy savings.
FEATURES
Motor switch ride through – during maintenance the motor disconnect switch can be opened and closed without stopping or tripping the drive.
Thin film capacitors – eliminate the need to condition or reform the capacitors before applying power.
View/monitor nine parameters at one time – users determine the parameters for their applications.
Smallest type 12 footprint on the market – lower shipping cost and easy installation.
Standard Integration Protocols (APOGEE® P1, BACnet, Modbus, Metasys N2).
BT300 Conventional Bypass
OVERVIEW
The BT300 conventional bypass utilizes selector switches and indicator lights as primary functions.
FEATURES
Bypass start-up wizard
Diagnostic board with test points
Control logic short circuit protection
100,000 AIC short circuit rating
IBC 2012 Seismic Certified
OSHPD Certified
Compact design
BT300 Electronic Bypass
OVERVIEW
The BT300 electronic bypass option uses internal control boards that act as the brains and eliminate the control wiring, relay logic, and terminal blocks. Advanced built-in features are accessible from an electronic keypad.
FEATURES
Bypass start-up wizard
Remote bypass
Diagnostic board with test points
Control logic short circuit protection
100,000 AIC short circuit rating
Auto Bypass
Damper interlock
Essential service mode
Electronic override
View/monitor bypass parameters
Monitor and display which safety interlock is open
Control external devices via serial communication
Pass through I/O capabilities command up to 8 output points
View status of I/O points
Supports APOGEE P1, BACnet and Modbus protocols in bypass
IBC 2012 Seismic Certified
OSHPD Certified
Compact design